Comparison of the fretting corrosion behaviour of Ti-6Al-4V alloy and CP-Ti IN ringer’s solution

Sivakumar, B and Satendra, Kumar and Sankara Narayanan, T S N (2011) Comparison of the fretting corrosion behaviour of Ti-6Al-4V alloy and CP-Ti IN ringer’s solution. Tribology - Materials, Interfaces and Surfaces, 5(4) (1.553). pp. 158-164.

[thumbnail of COMPARISON_OF_THE_FRETTING_CORROSION_BEHAVIOUR_of_TAV_and_CP-Ti.pdf] PDF
COMPARISON_OF_THE_FRETTING_CORROSION_BEHAVIOUR_of_TAV_and_CP-Ti.pdf - Accepted Version
Restricted to NML users only. Others may use ->

Download (1MB) | Request a copy

Abstract

Fretting corrosion behaviour of Ti-6Al-4V alloy in Ringer’s solution was evaluated and compared with that of CP-Ti. Free corrosion potential (FCP), morphology of the fretted zone, extent of formation and accumulation of debris and, wear volume were used as parameters of evaluation. Both Ti-6Al-4V alloy and CP-Ti behave similarly in terms of change in FCP as a function of time, morphological features and wear mechanism. Ti-6Al-4V alloy, however, exhibits an increase in corrosion susceptibility, decrease in tendency for repassivation, higher amount of formation and accumulation of debris and, an increase in wear volume, compared to that of CP-Ti. The study points out the importance of materials selection for implants that would encounter fretting corrosion.

Item Type: Article
Uncontrolled Keywords: Tribocorrosion; Fretting corrosion; Ti and its alloys; Implant; Joint prostheses; repassivation;
Subjects: Materials Science > Tribology
Metallurgy > Alloys and Compounds > Titanium Alloys
Materials Science > Biomaterials
Corrosion Science
Materials Science > Materials Charcterization
Divisions: NML Chennai > Chemistry