Chandramouli, V A and Balaramamoorthy, K and Kumar, J S (1968) Eddy Current Testing of Zircaloy Wires. In: Symposium on Non-ferrous Metals Technology : Papers for Presentation, 4th - 7th Dec. 1968, CSIR - National Metallurgical Laboratory, Jamshedpur.
![]() | PDF 564Kb |
Abstract
Fuel bundles for Rajasthan Atomic Power Reactor, consist of a cluster of 19 elements held together by zir-caloy and plates and spaced by wire helices on the six elements of the inner ring and alternative elements of the outer ring. As in the case of all other reactor mater-ials, the zircaloy wire also need be inspected 100% to avoid any defective part entering the reactor system. The zircaloy wire must be free from defects such as seams, internal voids, welded spots etc apart from the dimensio-nal and metallurgical requirements.
Item Type: | Conference or Workshop Item (Lecture) |
---|---|
Official URL/DOI: | http://eprints.nmlindia.org/4502 |
Uncontrolled Keywords: | Zircaloy wires; Current Testing; electromagnetic test |
Divisions: | Metal Extraction and Forming |
ID Code: | 4502 |