Guha, B K and Gupte, P K and Nijhawan, B R (1961) Failure of boiler tube by differential aeration corrosion. NML Technical Journal, 3 (4). pp. 16-20.
![]() | PDF Restricted to NML users only. Others may use -> 1977Kb |
Abstract
Details of an investigation into the cause of tube failure of a power house water tube boiler is described. Results of the findings indicated the failure to have been caused by the differential aeration phenomenon. Remedial measures have been recommended. (Mr. B.K. Guha, Junior Scientific Officer; Mr. P.K. Gupte, Assistant Director; Dr. B.R. Nijhawan, National Metallurgical Laboratory)
Item Type: | Article |
---|---|
Official URL/DOI: | http://library.nmlindia.org/articleDetails.jsp?rec... |
Uncontrolled Keywords: | Power house water tube boiler; Failure of boiler tubes |
Divisions: | Director Office |
ID Code: | 1440 |
Deposited By: | Dr. A K Sahu |
Deposited On: | 09 Aug 2010 17:33 |
Last Modified: | 08 Feb 2012 15:39 |
Related URLs: |
Repository Staff Only: item control page