Failure Analysis of SA213-T22 Re-heater Rear Tube of Thermal Power Plant

Metya, Avijit and Munda, Parikshit and Rajnikanth, V and Roy, Rajat (2016) Failure Analysis of SA213-T22 Re-heater Rear Tube of Thermal Power Plant. Transactions of the Indian Institute of Metals, 69(2) (IF-0.533). pp. 665-668.

[thumbnail of Failure_Analysis_of_SA213-T22_Re-heater_Rear_Tube_of_Thermal_Power_Plant.pdf] PDF
Failure_Analysis_of_SA213-T22_Re-heater_Rear_Tube_of_Thermal_Power_Plant.pdf - Published Version
Restricted to NML users only. Others may use ->

Download (967kB) | Request a copy

Abstract

SA213-T22 steel had been widely used in
petrochemical and power generation plants. But due to
prolonged service exposure in various conditions, these tubes have been ageing continuously and deteriorations of the materials cannot be avoided. This paper presents a case study of SA213 type-T22 alloy steel reheater tube that failed in a boiler of a power plant. The failed tube was investigated through visual examination, mechanical properties evaluation, and microstructural analysis to find the root cause of failure. The tube was found to fail by long term over-heating due to formation of thick oxide scale formation leading to creep.

Item Type: Article
Uncontrolled Keywords: SA213-T22 steel,Reheater tube ,Over-heating, Finite element simulation
Subjects: Metallurgy > Structural Properties
Divisions: Material Science and Technology
Depositing User: Dr. Avijit Kr. Metya
Date Deposited: 21 Jan 2016 12:29
Last Modified: 18 Jun 2020 04:57
URI: http://eprints.nmlindia.org/id/eprint/7380