Failure Analysis of A 304 SS Girdling Loop of the Boiler in a 500 MW Thermal Power Plant

Gnanamoorthy, J B and Jayakumar, T and Raj, Baldev (1995) Failure Analysis of A 304 SS Girdling Loop of the Boiler in a 500 MW Thermal Power Plant. In: Proceedings of the National Workshop on Boiler Corrosion (NWBC-95), April 11-12, 1995, NML, Jamshedpur.

[thumbnail of K1-K10.PDF] PDF
K1-K10.PDF

Download (3MB)

Abstract

There were many cases of girdling loop failures in the reheater section of the 500 MW boilers of athermal power station after being in service relatively for a short period of a few months. Within seven months of synchron-ization, the bottom 'U'portion of the front reheater
girdling loop of the boiler of 500 MW thermal power
plant had developed a leak. The plant was restarted
alter replacing the failed protion of the type 304 stain-less steel 'U' tube. Failure occurred again within seven
months of operation. Similar failures followed in the other units of the station.

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: Synchronization, Stereomicroscopic, Reheater section
Subjects: Corrosion Science
Divisions: Corrosion and Surface Engineering
Depositing User: Users 5 not found.
Date Deposited: 21 Jul 2011 06:29
Last Modified: 02 Dec 2011 07:00
URI: http://eprints.nmlindia.org/id/eprint/3560