Gnanamoorthy, J B and Jayakumar, T and Raj, Baldev (1995) Failure Analysis of A 304 SS Girdling Loop of the Boiler in a 500 MW Thermal Power Plant. In: Proceedings of the National Workshop on Boiler Corrosion (NWBC-95), April 11-12, 1995, NML, Jamshedpur.
| PDF 2967Kb |
Abstract
There were many cases of girdling loop failures in the reheater section of the 500 MW boilers of athermal power station after being in service relatively for a short period of a few months. Within seven months of synchron-ization, the bottom 'U'portion of the front reheater girdling loop of the boiler of 500 MW thermal power plant had developed a leak. The plant was restarted alter replacing the failed protion of the type 304 stain-less steel 'U' tube. Failure occurred again within seven months of operation. Similar failures followed in the other units of the station.
| Item Type: | Conference or Workshop Item (Paper) |
|---|---|
| Official URL/DOI: | http://eprints.nmlindia.org/3560 |
| Uncontrolled Keywords: | Synchronization, Stereomicroscopic, Reheater section |
| Divisions: | Corrosion and Surface Engineering |
| ID Code: | 3560 |
| Deposited By: | INVALID USER |
| Deposited On: | 21 Jul 2011 11:59 |
| Last Modified: | 02 Dec 2011 12:30 |
| Related URLs: |
Repository Staff Only: item control page

