Jha, N N and Singh, R K P and Jagannathan, K P and Jha, Ajit S and Singh, R P and kumar, B A and Sahu, S R and Singh, S B and Bose, P K and Pande, A M and Biswas, S K and Gupta, K N (1987) DRI as a coolant in BOF at Bokaro Steel Ltd. NML Technical Journal, 29 (1-4). pp. 25-32.
25-32.PDF
Restricted to NML users only. Others may use ->
Download (1MB) | Request a copy
Official URL/DOI: http://library/articleDetails.jsp?recordid=435
Abstract
Direct reduced iron, (DRI), can replace scrap to cool Basic Oxygen Furnace (BOF) heats. DRI as a coolant can efficiently be used requiring no modification. The paper explains the detail of such experiment, which consumed 400 tonnes of DRI in about 40 experimental heats in the 100/130 t BOF at BSL. The finer differences between the scrap cooled heats and DRI cooled experimental heats are elaborated in the paper.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Direct reduced iron; Basic Oxygen Furnace heats; Coolant |
| Subjects: | Metallurgy |
| Divisions: | Metal Extraction and Forming |
| Depositing User: | Dr. A K Sahu |
| Date Deposited: | 06 Jan 2011 05:42 |
| Last Modified: | 27 Dec 2013 11:42 |
| URI: | http://eprints.nmlindia.org/id/eprint/2322 |