DRI as a coolant in BOF at Bokaro Steel Ltd.

Jha, N N and Singh, R K P and Jagannathan, K P and Jha, Ajit S and Singh, R P and kumar, B A and Sahu, S R and Singh, S B and Bose, P K and Pande, A M and Biswas, S K and Gupta, K N (1987) DRI as a coolant in BOF at Bokaro Steel Ltd. NML Technical Journal, 29 (1-4). pp. 25-32.

[thumbnail of 25-32.PDF] PDF
25-32.PDF
Restricted to NML users only. Others may use ->

Download (1MB) | Request a copy

Abstract

Direct reduced iron, (DRI), can replace scrap to cool Basic Oxygen Furnace (BOF) heats. DRI as a coolant can efficiently be used requiring no modification. The paper explains the detail of such experiment, which consumed 400 tonnes of DRI in about 40 experimental heats in the 100/130 t BOF at BSL. The finer differences between the scrap cooled heats and DRI cooled experimental heats are elaborated in the paper.

Item Type: Article
Uncontrolled Keywords: Direct reduced iron; Basic Oxygen Furnace heats; Coolant
Subjects: Metallurgy
Divisions: Metal Extraction and Forming
Depositing User: Dr. A K Sahu
Date Deposited: 06 Jan 2011 05:42
Last Modified: 27 Dec 2013 11:42
URI: http://eprints.nmlindia.org/id/eprint/2322