Ghosh, M K and Gopalkrishna, S V and Chakrabarti, H K (1971) Spectrographic method of determination of niobium in steel. NML Technical Journal, 13 (4). pp. 100-103.
100-103.PDF
Restricted to NML users only. Others may use ->
Download (82kB) | Request a copy
Abstract
Small amounts of niobium, both in mild steel and stainless steel, have been determined by ac intermittent arc and point to plane spark technique respectively using secondary solid standards. Niobium in the range of 0.01 to 0.2% in mild steel and 0.1 to 1.0% in stainless steel was determined by this method with reproducible results having good agreement with chemical results. (Shri M.K. Ghosh, Scientist; Shri S.V. Gopalkrishna, Senior Laboratory Assistant; and Shri H.K. Chakrabarti, Scientist and Head of Chemical Division; National Metallurgical Laboratory)