Failure analysis of an isolation valve of LPG storage tank

Sinha, A N and Ranganath, V R and Das, N K and Mohanty, O N (1994) Failure analysis of an isolation valve of LPG storage tank. NML Technical Journal, 36 (3). pp. 83-94.

[thumbnail of 83-94.PDF] PDF
83-94.PDF
Restricted to NML users only. Others may use ->

Download (2MB) | Request a copy

Abstract

A detailed investigation has been carried out for analysing the failure of an isolation valve fitted to a LPG storage tank. The analysis carried-out included chemical composition, metallography, fractography and fracture toughness evaluation. This case study shows that the 'normal' defects which would pass through non-destructive examination, during quality control, could combine leading to catastrophic failure, during service.

Item Type: Article
Uncontrolled Keywords: LPG storage tanks; Fractography; Isolation valve fitted
Subjects: Metallurgy
Divisions: Metal Extraction and Forming
Depositing User: Users 5 not found.
Date Deposited: 13 Sep 2010 06:59
Last Modified: 27 Mar 2012 09:22
URI: http://eprints.nmlindia.org/id/eprint/1569