Abstract

Spectrographic analysis of high chromium-manganese-nitrogen austenitic stainless steel by porous cup technique, using neutral filter has been outlined in this paper. This method allows rapid and accurate determination of high percentage of chromium and manganese in nickel free austenitic stainless steel. Chromium upto 25 percent and manganese up to 18 percent have been estimated with an accuracy of +/- 4 percent using high voltage condensed spark. Neutral filter has been used to reduce the high intensity of the chromium and manganese also suitable for determining chromium and nickel in nickel-bearing austenitic stainless steels.

Item Type:Project Reports (Other (TMP))
Uncontrolled Keywords:Porous cup techniques, spectrographic method, high chromium-manganese-nitrogen austenitic, neutral filter