Demagnetisation effect and its correction on the measurement of magnetic hysteresis loop of melt-spun ribbons

Panda, A K and Basu, S and Mitra, A (2003) Demagnetisation effect and its correction on the measurement of magnetic hysteresis loop of melt-spun ribbons. Journal of Magnetism and Magnetic Materials, 261 (1-2). pp. 190-195.

[img]PDF
Restricted to NML users only. Others may use ->

175Kb

Abstract

Demagnetisation field arising from the free poles at the ribbon ends makes the measurement of hysteresis loop inaccurate for melt-spun high permeability ribbon shaped sample. No standard equation is also available for calculation of demagnetisation factor for such samples. In the present paper, attempts have been made to use empirical relations for demagnetisation correction of ribbon shaped FeNbCuSiB based material having thickness of the order of 35 μm. To the first approximation the material was considered as a cylinder with the equivalent cross-sectional area of the ribbon. A pre-factor, φ, was multiplied with the demagnetisation factor for equivalent cylindrical specimen to get the corrected demagnetisation factor of the measured sample. φ=0.65 was found to be the optimum pre-factor for the demagnetisation corrected hysteresis loop.

Item Type:Article
Official URL/DOI:http://dx.doi.org/10.1016/S0304-8853(02)01472-5
Uncontrolled Keywords:Demagnetisation correction; Ribbon sample; Amorphous soft magnetic material; Hysteresis loop
Divisions:Material Science and Technology
ID Code:549
Deposited By:Sahu A K
Deposited On:18 May 2010 10:16
Last Modified:06 Feb 2012 17:36
Related URLs: