Determination of Low Amount of Chromium in Alloy Steel by an Amplification Method

Sircar, J K and Bhattacharjee, S and Konar, J and Ghosh, K C and Basak, A C and Jha, S N and Pandey, L P (1996) Determination of Low Amount of Chromium in Alloy Steel by an Amplification Method. Microchemical Journal, 54 (2). pp. 163-167.

[img]PDF
Restricted to NML users only. Others may use ->

1298Kb

Abstract

An amplification method has been described for the determination of chromium in low alloy steel samples. The well-known Leipert reaction has been coupled with a precipitate exchange reaction between lead iodate and chromium(III)–EDTA complex for amplification. Chromium is determined indirectly by determinig the liberated iodine and the detection of chromium is amplified twelvefold.

Item Type:Article
Official URL/DOI:http://dx.doi.org/10.1006/mchj.1996.0089
Uncontrolled Keywords:Low Amount of Chromium;Alloy Steel by an Amplification Method
Divisions:Corrosion and Surface Engineering
ID Code:502
Deposited By:Sahu A K
Deposited On:14 May 2010 11:15
Last Modified:09 Feb 2012 16:43

Repository Staff Only: item control page