Parida, N and Tarafder, S (2001) Failure analysis of turbo-generator of a 10 MW captive power plant. Engineering Failure Analysis, 8 (3). pp. 303-309.
PDF - Published Version Restricted to NML users only. Others may use -> 1008Kb |
Abstract
The failure analysis of a disc and a few of the rotor parts of a turbo-generator of a 10 MW captive power plant has been made. It was found that a part of the rim of the 23rd disc, which had cracked by fatigue, became unstable and was flung off. This hit the diaphragm and the diaphragm carrier in its vicinity and led to their catastrophic failure.
Item Type: | Article |
---|---|
Official URL/DOI: | http://dx.doi.org/10.1016/S1350-6307(00)00002-9 |
Uncontrolled Keywords: | Turbine failures; Fatigue; Power-plant failures; Stress concentrations |
Divisions: | Material Science and Technology |
ID Code: | 353 |
Deposited By: | INVALID USER |
Deposited On: | 07 Dec 2009 18:17 |
Last Modified: | 07 Feb 2012 14:47 |
Related URLs: |
Repository Staff Only: item control page