DRI as a coolant in BOF at Bokaro Steel Ltd.

Jha, N N and Singh, R K P and Jagannathan, K P and Jha, Ajit S and Singh, R P and kumar, B A and Sahu, S R and Singh, S B and Bose, P K and Pande, A M and Biswas, S K and Gupta, K N (1987) DRI as a coolant in BOF at Bokaro Steel Ltd. NML Technical Journal, 29 (1-4). pp. 25-32.

[img]PDF
Restricted to NML users only. Others may use ->

1950Kb

Abstract

Direct reduced iron, (DRI), can replace scrap to cool Basic Oxygen Furnace (BOF) heats. DRI as a coolant can efficiently be used requiring no modification. The paper explains the detail of such experiment, which consumed 400 tonnes of DRI in about 40 experimental heats in the 100/130 t BOF at BSL. The finer differences between the scrap cooled heats and DRI cooled experimental heats are elaborated in the paper.

Item Type:Article
Official URL/DOI:http://library/articleDetails.jsp?recordid=435
Uncontrolled Keywords:Direct reduced iron; Basic Oxygen Furnace heats; Coolant
Divisions:Metal Extraction and Forming
ID Code:2322
Deposited By:Dr. A K Sahu
Deposited On:06 Jan 2011 11:12
Last Modified:27 Dec 2013 17:12
Related URLs: