Jha, N N and Singh, R K P and Jagannathan, K P and Jha, Ajit S and Singh, R P and kumar, B A and Sahu, S R and Singh, S B and Bose, P K and Pande, A M and Biswas, S K and Gupta, K N (1987) DRI as a coolant in BOF at Bokaro Steel Ltd. NML Technical Journal, 29 (1-4). pp. 25-32.
PDF Restricted to NML users only. Others may use -> 1950Kb |
Abstract
Direct reduced iron, (DRI), can replace scrap to cool Basic Oxygen Furnace (BOF) heats. DRI as a coolant can efficiently be used requiring no modification. The paper explains the detail of such experiment, which consumed 400 tonnes of DRI in about 40 experimental heats in the 100/130 t BOF at BSL. The finer differences between the scrap cooled heats and DRI cooled experimental heats are elaborated in the paper.
Item Type: | Article |
---|---|
Official URL/DOI: | http://library/articleDetails.jsp?recordid=435 |
Uncontrolled Keywords: | Direct reduced iron; Basic Oxygen Furnace heats; Coolant |
Divisions: | Metal Extraction and Forming |
ID Code: | 2322 |
Deposited By: | Dr. A K Sahu |
Deposited On: | 06 Jan 2011 11:12 |
Last Modified: | 27 Dec 2013 17:12 |
Related URLs: |
Repository Staff Only: item control page