Jha, N N and Singh, R K P and Jagannathan, K P and Jha, Ajit S and Singh, R P and kumar, B A and Sahu, S R and Singh, S B and Bose, P K and Pande, A M and Biswas, S K and Gupta, K N (1987) DRI as a coolant in BOF at Bokaro Steel Ltd. NML Technical Journal, 29 (1-4). pp. 25-32.
| PDF Restricted to NML users only. Others may use -> 1950Kb |
Abstract
Direct reduced iron, (DRI), can replace scrap to cool Basic Oxygen Furnace (BOF) heats. DRI as a coolant can efficiently be used requiring no modification. The paper explains the detail of such experiment, which consumed 400 tonnes of DRI in about 40 experimental heats in the 100/130 t BOF at BSL. The finer differences between the scrap cooled heats and DRI cooled experimental heats are elaborated in the paper.
| Item Type: | Article |
|---|---|
| Official URL/DOI: | http://library/articleDetails.jsp?recordid=435 |
| Uncontrolled Keywords: | Direct reduced iron; Basic Oxygen Furnace heats; Coolant |
| Divisions: | Metal Extraction and Forming |
| ID Code: | 2322 |
| Deposited By: | Dr. A K Sahu |
| Deposited On: | 06 Jan 2011 11:12 |
| Last Modified: | 27 Dec 2013 17:12 |
| Related URLs: |