Konar, J and Banerjee, N G (1974) Vacuum heating hydrogen determination in aluminium and aluminium alloys. NML Technical Journal, 16 (1-2). pp. 18-19.
| PDF Restricted to NML users only. Others may use -> 683Kb |
Abstract
Estimation of hydrogen in aluminium and aluminium alloys by hot vacuum extraction method has been carried out at different temperatures starting from 600°C to 1200°C. The authors have established that 900°C is the optimum temperatures for the complete extraction of hydrogen. Below that temperature complete extraction could not be achieved. Shri J. Konar and Shri N.G. Banerjee, Scientists, National Metallurgical Laboratory)