Konar, J and Banerjee, N G (1974) Vacuum heating hydrogen determination in aluminium and aluminium alloys. NML Technical Journal, 16 (1-2). pp. 18-19.
PDF Restricted to NML users only. Others may use -> 683Kb |
Abstract
Estimation of hydrogen in aluminium and aluminium alloys by hot vacuum extraction method has been carried out at different temperatures starting from 600°C to 1200°C. The authors have established that 900°C is the optimum temperatures for the complete extraction of hydrogen. Below that temperature complete extraction could not be achieved. Shri J. Konar and Shri N.G. Banerjee, Scientists, National Metallurgical Laboratory)
Item Type: | Article |
---|---|
Official URL/DOI: | http://library/articleDetails.jsp?recordid=319 |
Uncontrolled Keywords: | Hot vacuum extraction method-Aluminium |
Divisions: | Metal Extraction and Forming |
ID Code: | 2158 |
Deposited By: | Dr. A K Sahu |
Deposited On: | 22 Dec 2010 10:05 |
Last Modified: | 16 Mar 2012 10:46 |
Related URLs: |