Cracking of Brass Tubes in Sugar Juice Evaporators - A Case Study

Lahiri, A K and Bhakta, U C (1971) Cracking of Brass Tubes in Sugar Juice Evaporators - A Case Study. NML Technical Journal, 13 (4). pp. 109-110.

[img]PDF
Restricted to NML users only. Others may use ->

96Kb

Abstract

The paper gives the details of investigation on the cracking of 70130 brass tubes in sugar juice evaporator. The failure was found to be due to stress corrosion cracking, in presence of ammonia released from sugar juice.

Item Type:Article
Official URL/DOI:http://www.nmlindia.org
Uncontrolled Keywords:Brass; Sugar juice evaporator
Divisions:Corrosion and Surface Engineering
ID Code:2102
Deposited By:Dr. A K Sahu
Deposited On:16 Dec 2010 10:10
Last Modified:14 Mar 2012 12:46
Related URLs: