Spectrographic analysis of nodular cast iron for magnesium

Ghosh, M K and Chakrabarti, H K (1970) Spectrographic analysis of nodular cast iron for magnesium. NML Technical Journal, 12 (4). pp. 97-100.

[img]PDF
Restricted to NML users only. Others may use ->

1002Kb

Abstract

A spectrographic method of determination of magnesium in nodular cast iron by solution technique using synthetic standards has been described in this paper. Both porous graphite cup and rotating electrode methods have been adopted for these determination and their results have been compared with that of solid standard method. Results appear to be reproducible and co-efficient of variation ranges from 4 to 7%. (Shri M.K. Ghosh, Scientist and Shri H.K. Chakrabarti, Scientist & Head of Chemistry Division, National Metallurgical Laboratory, Jamshedpur)

Item Type:Article
Official URL/DOI:http://library/articleDetails.jsp?recordid=247
Uncontrolled Keywords:Nodular cast iron-Magnesium; Porous graphite cup
Divisions:Analytical Chemistry
ID Code:2070
Deposited By:Dr. A K Sahu
Deposited On:22 Nov 2010 17:02
Last Modified:07 Mar 2012 17:00
Related URLs:

Repository Staff Only: item control page