Evaluation of manganese-copper-nickel alloys for use in thermobimetal

Bhattacharya, J and Das, B N (1970) Evaluation of manganese-copper-nickel alloys for use in thermobimetal. NML Technical Journal, 12 (1). pp. 9-11.

[img]PDF
Restricted to NML users only. Others may use ->

743Kb

Abstract

The paper discusses the various requirements of high expansion alloys used in thermobimetal, with a short review of commonly used alloys. Thermal expansion at different temperature ranges (from 30°C to 400°C), hardening due to cold rolling and recrystallization characteristics of five Mn-Cu-Ni alloys were studied with a view to evaluating their use in thermobimetal. It was found that Mn-Cu-Ni alloy with 75% Mn, 15% Ni and 10% copper gives comparably higher range of lenearity of the coefficient of expansion in the series and its mechanical properties and thermal stability makes it highly suitable for high sensivity thermobimetals. (Shri J. Bhattacharya, Scientist and Shri B.N. Das, Scientist and Head, Mechanical Metallurgy & Testing Division; National Metallurgical Laboratory, Jamshedpur)

Item Type:Article
Official URL/DOI:http://library/articleDetails.jsp?recordid=230
Uncontrolled Keywords:High expansion alloys; Mn-Cu-Ni alloys; High sensivity thermobimetals
Divisions:Metal Extraction and Forming
ID Code:2009
Deposited By:Dr. A K Sahu
Deposited On:24 Oct 2010 10:21
Last Modified:07 Mar 2012 14:22
Related URLs:

Repository Staff Only: item control page