Ghose, M K and Debnath, P C and Kar, B C (1964) Spectrochemical determination of antimony in lead-tin-solders. NML Technical Journal, 6 (3). pp. 6-9.
PDF Restricted to NML users only. Others may use -> 1238Kb |
Abstract
Spectrographic methods for accurate and rapid determination of both high and low antimony contents in solders have been discussed. Porous cup technique was adopted for estimation of high amount of antimony upto 10percent and oxide arc technique was adopted for antimony upto a lower limit of 0'001 percent. Analytical accuracy varied from 3 to 6 percent of the amount present when the concentration of the element to be determined is low. At higher concentration, however, lower values were obtained for both precision and accuracy. (Mr. M.K. Ghose, Senior Scientific Officer; Mr. P.C. Debnath, Junior Scientific Assistant; Dr. B.C. Kar, Assistant Director; National Metallurgical Laboratory, Jamshedpur)
Item Type: | Article |
---|---|
Official URL/DOI: | http://library/articleDetails.jsp?recordid=111 |
Uncontrolled Keywords: | Antimony; Spectrographic methods |
Divisions: | Metal Extraction and Forming |
ID Code: | 1723 |
Deposited By: | Dr. A K Sahu |
Deposited On: | 27 Sep 2010 09:46 |
Last Modified: | 16 Feb 2012 16:31 |
Related URLs: |
Repository Staff Only: item control page