Mukherjee, K P and Lahiri, A K and Banerjee, T (1960) Erosion of induced draft fan in thermal power station. NML Technical Journal, 2 (3). pp. 7-11.
PDF Restricted to NML users only. Others may use -> 1455Kb |
Abstract
The efficiency and economy of power generating plants depend largely on the minimisation of breakdown in various units. A serious case of damage of induced draft fan at the Bokaro Thermal Power Station was investigated. The paper describes various tests carried out to determine the causes of damage. The investigation indicated that localised erosive action of fly ash played an important part in causing the damage. Suitable preventive measures on the basis of the investigation were suggested. (Mr. K.P. Mukherjee, Senior Scientific Assistant; Mr. A.K. Lahiri, Junior Scientific Officer; Dr. T. Banerjee, Deputy Director, National Metallurgical Laboratory, Jamshedpur)