Lahiri, A K and Banerjee, T (1959) Cavitation Erosion-A case of conjoint action. NML Technical Journal, 1 (2). pp. 38-40.
![]() | PDF Restricted to NML users only. Others may use -> 977Kb |
Abstract
Cavitation erosion has been attributed to a conjointed action of chemical and mechanical factors giving rise to a very serious type of erosion. A case of serious failure of cast iron pump impeller by cavitation erosion investigated at the National Metallurgical Laboratory, showed that the hammering effect of collapsing cavities and corrosion by chlorides and chlorine were the root cause of attack. Preventive measures suggested in this connection include control of water pressure head at the pump inlet, choice of metal, perfection in design etc. (Mr. A.K. Lahiri, Junior Scientific Officer and Dr. T. Banerjee, Deputy Director, National Metallurgical Laboratory, Jamshedpur)
Item Type: | Article |
---|---|
Official URL/DOI: | http://library.nmlindia.org/articleDetails.jsp?rec... |
Uncontrolled Keywords: | Preventive measures ; cavitation erosion |
Divisions: | Director Office |
ID Code: | 1393 |
Deposited By: | Dr. A K Sahu |
Deposited On: | 09 Aug 2010 12:14 |
Last Modified: | 01 Feb 2012 11:31 |
Related URLs: |
Repository Staff Only: item control page