Corrosion of Brine Storage Tank

Mukherjee, K P and Lahiri, A K and Banerjee, T (1961) Corrosion of Brine Storage Tank. Other (TMP). CSIR-NML, Jamshedpur, Jamshedpur.

[thumbnail of Corrosion of Brine Storage Tank] PDF (Corrosion of Brine Storage Tank)
IR_200-61.pdf - Published Version
Restricted to NML users only. Others may use ->

Download (4MB) | Request a copy

Abstract

The Subject of corrosion in Brine Storage Tanks was refereed to far investigation by Messrs. The D.C.M. Chemical Works to the National Metallurgical Laboratory. The brine tanks used for feeding saturated sodium chloride electrolyte to the caustic soda cell were found to fail prematuredly by pitting. The corrosion attack was most severe in the intermittently exposed areas originating from the rising and falling of the level of the feed solution. Before taking up this investigation, a visit was made to the plant to study site conditions that had caused the corrosion. A detailed plan of investigation was drawn up to study the effects of various factors responsible for the type of corrosion attack observed and to suggest possible remedial measures.

Item Type: Project Reports (Other (TMP))
Uncontrolled Keywords: Brine storage tank, corrosion, sodium chloride electrolyte, caustic soda
Subjects: Corrosion Science
Divisions: Information Management and Dissemination Centre
Depositing User: Users 43 not found.
Date Deposited: 01 Apr 2022 12:23
Last Modified: 10 Jun 2022 09:05
URI: http://eprints.nmlindia.org/id/eprint/8598

Actions (login required)

View Item
View Item