Abstract
Iron causes severe depression of the signal in determination of chromium by atomic-absorption spectrophotometry in an air—acetylene flame. This effect can be eliminated by addition of hydroxylamine hydrochloride and use of a fuel-rich flame. Addition of iron to the standard solutions is not necessary for up to 300 ppm of iron in the test solution.