Swaminathan, J and Krishna, G and Gunjan, M K and Mahato, B and Ravi Kumar, B and Hansda, K L and Sharma, R K and Upadhyay, A K (2007) Failure Analysis of Water wall Tubes of Boiler No.7. Sponsored (SSP). CSIR-NML, Jamshedpur. (Submitted)
Full text not available from this repository. (Request a copy)
Official URL/DOI: http://eprint.nmlindia.org/6505
Abstract
Failures were reported in the waterwall tubes of boiler no.7 of BPSCL, Bokaro. Systematic investigation carried out on the failed and un-failed tubes revealed that corrosion on the waterside of the tubes is the main reason for the failure.
| Item Type: | Project Reports (Sponsored (SSP)) |
|---|---|
| Uncontrolled Keywords: | Boiler tube failure; fireside corrosion; water side scaling |
| Subjects: | Materials Science |
| Divisions: | Material Science and Technology |
| Depositing User: | Users 5 not found. |
| Date Deposited: | 12 Jul 2013 04:44 |
| Last Modified: | 12 Jul 2013 04:45 |
| URI: | http://eprints.nmlindia.org/id/eprint/6505 |