Berg, Frenk van den and Yang, Haibing (2011) Real-time Meniscus Level and Slag Thickness Measurement by RADAR. In: Proceedings of the International Conference on Non Destructive Evaluation for Steel and Allied Industries - NDESAI 2011, Dec. 2-3, 2011, SNTI Auditorium Jamshedpur, India.
Preview
21-28.pdf
Download (1MB)
Official URL/DOI: http://eprints.nmlindia.org/4603
Abstract
In part I of the papaer [1], an ultra-wideband RADAR system has been described which serves as prototype for highly resolution studies in monitoring slag thickness
and meniscus level in a continuous cast system. In the second part here, results of trials on liquid steel confirming the fine resolution capability of the system are presented, as well as data on the evolution of the slag thickness in time during heating.
| Item Type: | Conference or Workshop Item (Paper) |
|---|---|
| Uncontrolled Keywords: | Prototype; experimental conditions; reference measurements; liquid steel |
| Subjects: | Materials Science Materials Science > Materials Charcterization |
| Divisions: | Material Science and Technology |
| Depositing User: | Users 5 not found. |
| Date Deposited: | 14 Jan 2012 06:11 |
| Last Modified: | 03 Sep 2026 05:45 |
| URI: | http://eprints.nmlindia.org/id/eprint/4603 |