Spectrographic analysis of low alloy steels by solution technique

Ghosh, M K (1970) Spectrographic analysis of low alloy steels by solution technique. NML Technical Journal, 12 (3). pp. 74-77.

[thumbnail of 74-77.PDF] PDF
74-77.PDF
Restricted to NML users only. Others may use ->

Download (939kB) | Request a copy

Abstract

A spectrographic method for analysis of low alloy steels by the solution-porous cup technique using synthetic standards has been described in this paper. Solutions of the samples were introduced in specially prepared porous graphite cups serving as upper electrodes and high voltage spark was used for excitation. Reproducible results, which are in good agreement with chemical results, have been obtained by this method. (Shri M.K. Ghosh, Scientist, National Metallurgical Laboratory, Jamshedpur)

Item Type: Article
Uncontrolled Keywords: Porous graphite cups; Low alloy steels
Subjects: Materials Science
Divisions: Material Science and Technology
Depositing User: Dr. A K Sahu
Date Deposited: 22 Nov 2010 09:01
Last Modified: 07 Mar 2012 10:20
URI: http://eprints.nmlindia.org/id/eprint/2065