Effect of ph on corrosion inhibition of mild-steel by chromates

Bahadur, Aruna (1993) Effect of ph on corrosion inhibition of mild-steel by chromates. Materials Transactions JIM, 34 (12). pp. 1191-1194.

[thumbnail of Aruna_bahadur.PDF] PDF
Aruna_bahadur.PDF
Restricted to NML users only. Others may use ->

Download (1MB) | Request a copy
Official URL/DOI: http://www.nmlindia.org

Abstract

The paper outlines the effect of pH on corrosion inhibition of mild steel by chromates using radioactive tracer technique. It shows that Cr-uptake is more in the acidic region, less in the neutral zone and the least in the alkaline region. Therefore, raising the pH of inhibitor solution leads to reduced chromate consumption. It was found that chromate continues to passivate mild steel in pH range (3.4-10.0) for at least up to 7 h.

Item Type: Article
Uncontrolled Keywords: Radio Tracer Technique
Subjects: Materials Science
Divisions: Material Science and Technology
Depositing User: Users 5 not found.
Date Deposited: 09 Jun 2010 09:08
Last Modified: 13 Dec 2011 10:30
URI: http://ictu2016-114.nmlindia.org/id/eprint/922