Failure analysis of an isolation valve of LPG storage tank

Sinha, A N and Ranganath, V R and Das, N K and Mohanty, O N (1994) Failure analysis of an isolation valve of LPG storage tank. NML Technical Journal, 36 (3). pp. 83-94.

[img]PDF
Restricted to NML users only. Others may use ->

2718Kb

Abstract

A detailed investigation has been carried out for analysing the failure of an isolation valve fitted to a LPG storage tank. The analysis carried-out included chemical composition, metallography, fractography and fracture toughness evaluation. This case study shows that the 'normal' defects which would pass through non-destructive examination, during quality control, could combine leading to catastrophic failure, during service.

Item Type:Article
Official URL/DOI:http://library.nmlindia.org/articleDetails.jsp?rec...
Uncontrolled Keywords:LPG storage tanks; Fractography; Isolation valve fitted
Divisions:Metal Extraction and Forming
ID Code:1569
Deposited By:Sahu A K
Deposited On:13 Sep 2010 12:29
Last Modified:27 Mar 2012 14:52
Related URLs: